Min quantity:1Piece
Quantity:999Piece
Deliver:In 7 days
Overview
Essential details
Place of Origin:
China
Brand Name:
YOMIN
Model Number:
YEM081PD
Display Type:
Analog Only
Phase:
Three Phase
Measuring Energy Range:
5(30),10(60),20(120)A
Accuracy Class:
class 2
Output Voltage:
3X127/220,3X230/400V
Operating Temperature:
-20°C to + 60°C
Dimensions:
304.5x167.5x128MM
installed:
front board mounted
Type:
Three Phase Energy Meter
Display:
Register
Certificate:
RoHS/ISO/CE
Standard:
IEC62053-11
Frequency:
50Hz
Current:
3X20(120)A
Supply Ability
Supply Ability
20000 Piece/Pieces per Month for Energy Meter
Packaging & delivery
Packaging Details
Export Carton with Inner Foam Box for Energy Meter
Port
SHANGHAI/NINGBO for Energy Meter
Lead time:
7 days after order /confirm/iation
Front Board Installed Three Phase Power Meter with PC Cover Three Phase Energy Meter Three Phase Active Electric Meter
Model YEM081PD three phase four wire electromechanical front board installed active energy meter is a kind of new style three phase four wire active energy meter, it is designed on the basis of original three phase electromechanical meter, and fully absorbs new technologies about electromechanical meter from domestic and abroad, and development long-life technology. The meter completely accords with relevant technical requirements of class 2 three phase active energy meter stipulated in international standard IEC 62053-11. It can accurately and directly measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net, it is used for setting indoor or out door meter box, and it can display total energy consumption by drum wheel mechanical register. It has following features: high overload, power loss, long-life, specious appearance, etc.
Functions
1. Front board three fixed installation, up and down mounting holes center distance is 209 mm or 225mm, users can choose any one by themselves.
2. The cover is made of PC material which is transparent and anti-UV molded overall, the bottom of the meter and the terminal is made of quality bakelite material which is moisture-resistant, fire-retardant, high temperature molded overall. It has following features: good weatherability, high rigid, good insulation performance, etc.
3. The meter frame adopt top-quality steel plate once molding with excellent mechanical strength, stable structure and anti-impact.
4. Voltage components is used of all closed vacuum pouring coil by epoxy resin. Current components is used of double insulation structure, has good electrical characteristics.
5. The type meter adopt magnetic thrust bottom bearing, oriented bearing is made of lubrication graphite bush and stainless steel needle. It has following features: small abrasion, long life and minimal friction, etc.
6. All kinds of adjustment mechanism adopt no step shifting mechanism. The meter starting and creeping needn’t to be adjust which is finished by anti-creeping hole of disc and convenient for adjusting by users.
7. Standard configuration 6 digits display by drum wheel mechanical register, may select 7 digits display by drum wheel mechanical register (Product Configuration code is PJ).
8.Three components measure three phase four wire active energy consumption. Complying with standard IEC 62053-11.
9. Standard configuration for direct connect operation, type 16B wiring, we can also choose another type of wiring, and use CT (Product Configuration code is PE), type 48B wiring, and PT & CT (Product Configuration code is PF), type 48B wiring for operation.
10. Standard configuration extension terminals cover, in order to protect to use safety, may select short terminals cover. (Product Configuration code is OD)
Technical parameters
Model | Accuracy | Reference Voltage(V) | Current specifications(A) | Starting current(A) | Insulation performance | ||
YEM081PD | Class 2 | 3×127/220 3×230/400 | 5(30) 10(60) 20(120) | 0.025 0.05 0.1 | AC voltage 4kv for 1 minute, 1.2/50us waveform impulse voltage 8kv |
Dimension
Wiring Diagram
Terminals | Note | Terminals | Note | ||||||
1 | L1 inlet phase line | 7 | L3 inlet phase line | ||||||
3 | L1 outgoing phase line | 9 | L3 outgoing phase line | ||||||
4 | L2 inlet phase line | 10 | Inlet neutral line | ||||||
6 | L2 outgoing phase line | 11 | Outgoing neutral line |
Front B
1 Where is your factory?
Our factory is located in Qiaoqian Industry Area, Liushi Town, Yueqing City, Zhejiang Province, 325603 China.
2 Are you manufacturer or business?
We are manufacturer established in 2002, and have over 16 years production experience.
3. Can I ask for samples?
Yes
4. What's the warranty of your products?
18 months
5. What's the lead time?
Depend on the quantity and model of the order, normally it takes around 2-3 days, but the exact lead time should be discussed with our sales.
6. How about the MOQ, Payment term, Delivery port, and shipping date?
1)MOQ: 100 pcs/item based on existing packing.
2)T/T-30% deposit and 70% against copy of BL
3)L/C is also acceptable
4)Ningbo/Shanghai