Share BuyProducts Channel
1/6
Schneider LRD06 telemecanique thermal overload relay / 1Schneider LRD06 telemecanique thermal overload relay / 2Schneider LRD06 telemecanique thermal overload relay / 3Schneider LRD06 telemecanique thermal overload relay / 4Schneider LRD06 telemecanique thermal overload relay / 5Schneider LRD06 telemecanique thermal overload relay / 6

Schneider LRD06 telemecanique thermal overload relay

2022-11-04 11:2254910
Price:$19.76/sets
Min quantity:100sets
Quantity:10000sets

Overview

Essential details

Packaging & delivery

Schneider thermal overload relays LRD06

1...1.6A, class 10A with new design!

Product Description

>> What are the main features of Schneider thermal overload relays

    LRD06?

Main


Range

TeSys 

TeSys Deca

Range of product

TeSys D 

TeSys Deca

Product or component type

Differential thermal overload relay

Device short name

LRD

Relay application

Motor protection

Product compatibility

LC1D25 

LC1D32 

LC1D12 

LC1D18 

LC1D38 

LC1D09

Network type

DC 

AC

Thermal overload class

Class 10A conforming to IEC 60947-4-1

Thermal protection adjustment range

1…1.6 A

[Ui] rated insulation voltage

Power circuit: 600 V conforming to CSA 

Power circuit: 600 V conforming to UL 

Power circuit: 690 V conforming to IEC 60947-4-1

Network frequency

0...400 Hz

Mounting support

Plate, with specific accessories 

Rail, with specific accessories 

Under contactor

Tripping threshold

1.14 +/- 0.06 Ir conforming to IEC 60947-4-1

Auxiliary contact composition

1 NO + 1 NC

[Ith] conventional free air thermal current

5 A for signalling circuit

Permissible current

3 A at 120 V AC-15 for signalling circuit 

0.22 A at 125 V DC-13 for signalling circuit

[Ue] rated operational voltage

690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1

Associated fuse rating

4 A gG for signalling circuit 

4 A BS for signalling circuit

[Uimp] rated impulse withstand voltage

6 kV

Phase failure sensitivity

Tripping current 130 % of Ir on two phase, the last one at 0

Control type

Red push-button: stop 

Blue push-button: reset

Temperature compensation

-20…60 °C

Connections - terminals

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end 

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end 

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable end

Tightening torque

Control circuit: 1.7 N.m - on screw clamp terminals 

Power circuit: 1.7 N.m - on screw clamp terminals

>> What condition of the environment could Schneider thermal

    overload relays LRD06 be used?

Environment


Climatic withstand

conforming to IACS E10

IP degree of protection

IP20 conforming to IEC 60529

Ambient air temperature for operation

-20…60 °C without derating conforming to IEC 60947-4-1

Ambient air temperature for storage

-60…70 °C

Flame retardance

V1 conforming to UL 94

Mechanical robustness

Vibrations: 6 Gn conforming to IEC 60068-2-6 

Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7

Dielectric strength

1.89 kV at 50 Hz conforming to IEC 60947-1

Standards

EN/IEC 60947-4-1 

EN/IEC 60947-5-1 

UL 60947-4-1 

UL 60947-5-1 

CSA C22.2 No 60947-4-1 

CSA C22.2 No 60947-5-1 

GB/T 14048.4 

GB/T 14048.5 EN 50495

Product certifications

IEC

UL 

CSA 

CCC 

EAC 

BV 

RINA 

DNV-GL 

LROS (Lloyds register of shipping) 

ATEX INERIS 

UKCA

>> What is the dimension of Schneider thermal overload relayes

    LRD06?

Dimension


Height

66 mm

Width

45 mm

Depth

70 mm

Net weight

0.124 kg


Favorite 0
Comment 0
Contact
Buy