Overview
Essential details
Key word:
telemecanique thermal overload relay
type:
magnetic overload relay
Packaging & delivery
Selling Units:
Single item
Single package size:
40X30X30 cm
Single gross weight:
1.000 kg
Package Type:
150 *80*130MM per unit
Lead time:
Quantity(sets) | 1 - 1 | >1 |
Lead time (days) | 3 | To be negotiated |
Schneider thermal overload relays LRD06
1...1.6A, class 10A with new design!
Product Description
>> What are the main features of Schneider thermal overload relays
LRD06?
Main |
|
Range | TeSys TeSys Deca |
Range of product | TeSys D TeSys Deca |
Product or component type | Differential thermal overload relay |
Device short name | LRD |
Relay application | Motor protection
|
Product compatibility
| LC1D25 LC1D32 LC1D12 LC1D18 LC1D38 LC1D09
|
Network type
| DC AC |
Thermal overload class
| Class 10A conforming to IEC 60947-4-1
|
Thermal protection adjustment range
| 1…1.6 A
|
[Ui] rated insulation voltage | Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1 |
Network frequency | 0...400 Hz |
Mounting support
| Plate, with specific accessories Rail, with specific accessories Under contactor |
Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
|
Auxiliary contact composition | 1 NO + 1 NC |
[Ith] conventional free air thermal current | 5 A for signalling circuit
|
Permissible current
| 3 A at 120 V AC-15 for signalling circuit 0.22 A at 125 V DC-13 for signalling circuit
|
[Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
Associated fuse rating | 4 A gG for signalling circuit 4 A BS for signalling circuit |
[Uimp] rated impulse withstand voltage
| 6 kV |
Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0
|
Control type
| Red push-button: stop Blue push-button: reset |
Temperature compensation | -20…60 °C
|
Connections - terminals | Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable end |
Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals Power circuit: 1.7 N.m - on screw clamp terminals |
>> What condition of the environment could Schneider thermal
overload relays LRD06 be used?
Environment |
|
Climatic withstand | conforming to IACS E10
|
IP degree of protection | IP20 conforming to IEC 60529 |
Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
Ambient air temperature for storage | -60…70 °C
|
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6 Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495 |
Product certifications | IEC UL CSA CCC EAC BV RINA DNV-GL LROS (Lloyds register of shipping) ATEX INERIS UKCA |
>> What is the dimension of Schneider thermal overload relayes
LRD06?
Dimension |
|
Height | 66 mm |
Width | 45 mm |
Depth | 70 mm |
Net weight | 0.124 kg |