Hello, Welcome To VisitYueqing Yomin Electric Co., Ltd!
13968745082a
 
Home > Sell > Hot Sell127V 230V Single Phase Front Board Installation Analog Energy Meter KWH Meter Electric Meter
Hot Sell127V 230V Single Phase Front Board Installation Analog Energy Meter KWH Meter Electric Meter
Hits: 241
Price: 6.29Dollar/Piece
Min quantity: 1 Piece
Quantity: 999 Piece
Deliver: In 7 days
Expiry: Long-term
Update date 2023-01-04 16:48
 
Detail

Overview

Essential details

  • Place of Origin:

  • Zhejiang, China

  • Brand Name:

  • YOMIN

  • Model Number:

  • YEM074TI

  • Display Type:

  • Analog Only, Analog Only

  • Phase:

  • Single Phase

  • Measuring Energy Range:

  • 10(20),20(40),30(60),40(80)A

  • Accuracy Class:

  • class 2

  • Output Voltage:

  • 127,230V

  • Operating Temperature:

  • -20°C ~ + 60°C, -20℃~60℃

  • Dimensions:

  • 161x114x102mm, 161*114*102mm

  • installed:

  • front board mounted

  • Product name:

  • Front Board Mounted Energy Meter

  • Certificate:

  • CE ROHS

  • Cover Material:

  • PC

  • Bottom Materil:

  • Steel

  • Terminal:

  • Bakelite

  • Accuracy:

  • Class 2

Supply Ability

  • Supply Ability

  • 100000 Piece/Pieces per Month for Energy Meter

Packaging & delivery

  • Packaging Details

  • Mass order: Blister tray+Inner carton+Master carton+pallet.
    Sample Order: PE foam+printed box+master carton
  • Port

  • SHANGHAI/NINGBO for Energy Meter
  • Lead time:

  • Shipped in 4-20 days after payment, depend on order qty and stoc

Hot Sell127V 230V Single Phase Front Board Installation Analog Energy Meter KWH Meter Electric Meter with PC Transparent Cover

 

Product Description

Model YEM074TI single phase electromechanical front board setting active energy meter is a kind of new style single phase two wire active energy meter, it is designed on the basis of original DD282 single phase electromechanical meter, and fully absorb new technologies about electromechanical meter from domestic and abroad. The meter completely accords with relevant technical requirements of class 2 single phase active energy meter stipulated in international standard IEC 62053-11. It can accurately and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it is used for setting indoor or out door meter box. The meter has novel design, rational structure, and it can display total energy consumption by drum wheel mechanical register. It has following features: compact structure design, small size, economy benefits, specious appearance, etc.

Functions

1. Front board two fixed installation, the cover is made of PC material which is transparent and anti-UV molded overall, the bottom of the meter is made of quality steel which is after double-through antirust processing, and the terminal is made of quality bakelite material which is moisture-resistant, fire-retardant, high temperature molded overall.It has following features: economy benefits, specious appearance, etc.

 

2. The meter frame adopt aluminum molding with excellent mechanical strength, stable structure and anti-impact.

 

3. Voltage components and current components is used of double insulation structure, has good electrical characteristics.

 

4. Standard configuration voltage circuit and current circuit connect in the case, may select connect outside.

 

5. Standard configuration bottom bearing is used of single-precious stone bearing, oriented bearing is made of high wear resistance copper alloy bush and stainless steel needle. May select magnetic thrust bearing (Product Configuration code is TA) or double gem bearing (Product Configuration code is TE).

 

6. All kinds of error adjustment mechanism adopt no step shifting mechanism. The meter starting and creeping needn’t to be adjust which is finished by anti-creeping hole of disc and convenient for adjusting by users.

 

7. Standard configuration 5 digits display by drum wheel mechanical register, may select 6 digits display by drum wheel mechanical register (Product Configuration code is TK).

 

8. Standard configuration without the device which can prevent retrograde, may select add the function of prevent retrograde. (Please specified when ordering).

 

9. Single component measure single phase two wire active energy consumption. Complying with standard IEC 62053-11.

 

10. Direct connect operation, there are two types wiring you may select. Standard configuration type 1B wiring, may select type 1A wiring (Product Configuration code is TJ).

 

11. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is UI).

Technical parameters

 

Model

Accuracy

Reference

Voltage(V)

Current

specifications(A)

Starting

current

Insulation

performance

YEM074TI

Class 2

127

230

10(20)

20(40)

30(60)

40(80)

0.05

0.1

0.15

0.2

AC voltage 2kv for 1 minute,

1.2/50us waveform impulse voltage 6kv

 

Dimension

 Hot Sell127V 230V Single Phase Front Board Installation Analog Energy Meter KWH Meter Electric Meter with PC Transparent Cover 

Wiring Diagram

 

 

 

Hot Sell127V 230V Single Phase Front Board Installation Analog Energy Meter KWH Meter Electric Meter with PC Transparent Cover

Terminals

Note

1

Inlet phase line

3

Outgoing phase line

4

Inlet neutral line

5

Outgoing neutral line

 

Company Information

Hot Sell127V 230V Single Phase Front Board Installation Analog Energy Meter KWH Meter Electric Meter with PC Transparent CoverHot Sell127V 230V Single Phase Front Board Installation Analog Energy Meter KWH Meter Electric Meter with PC Transparent CoverHot Sell127V 230V Single Phase Front Board Installation Analog Energy Meter KWH Meter Electric Meter with PC Transparent Cover


Inquiry
Products type
  • N/A
Search
 
Link
  • N/A
13968745082a